Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 99
Filter
1.
Acta Pharmaceutica Sinica ; (12): 198-201, 2024.
Article in Chinese | WPRIM | ID: wpr-1005430

ABSTRACT

To establish and optimize a method for the detection of recombinant human midkine (rhMK) activity and verify its methodology, cell counting kit-8 (cck-8) method was used to measure the proliferation activity of rat knee chondrocytes. The specificity, accuracy, precision, linearity and robustness of the method were also verified in this study. The established method was proven to have good specificity because the buffer of rhMK and recombinant human interleukin-1 receptor antagonist have no obvious active effect; the recoveries of the samples with relative activities of 50%, 75%, 100%, 125%, 150% were in the range of 80.0% to 124.0% by statistical analysis, the relative standard deviations (RSD) of relative potency were all within 20%, the linear correlation coefficient, R2 ≥ 0.98, suggesting that the accuracy, precision and linearity of the method were good; the robustness correlation coefficient, R2 ≥ 0.92 and the ratio of maximum to minimum of sigmoidal dose-response were no less than 1.5, indicating that robustness of the methods was good. In conclusion, a bioactivity measurement method for rhMK was established and fully validated in this study and it provides a reliable method for the bioactivity analysis of rhMK routine samples during the development. This study was approved by the Animal Care and Use Committee of Shanghai Model Organisms Center, Inc. (approval number: 2019-0008-06).

2.
Journal of Pharmaceutical Analysis ; (6): 403-411, 2023.
Article in Chinese | WPRIM | ID: wpr-991153

ABSTRACT

Given that impurities may affect the quality and safety of drug products,impurity identification and profiling is an integral part of drug quality control and is particularly important for newly developed medications such as solriamfetol,which is used to treat excessive daytime sleepiness.Although the high-performance liquid chromatography analysis of commercial solriamfetol has revealed the presence of several impurities,their synthesis,structure elucidation,and chromatographic determination have not been reported yet.To bridge this gap,we herein identified,synthesized,and isolated eight process-related solriamfetol impurities,characterized them using spectroscopic and chromatographic tech-niques,and proposed plausible mechanisms of their formation.Moreover,we developed and validated a prompt impurity analysis method based on ultrahigh-performance liquid chromatography with UV detection,revealing that its selectivity,linearity,accuracy,precision,and quantitation limit meet the acceptance criteria of method validation stipulated by the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use.Thus,the developed method was concluded to be suitable for the routine analysis of solriamfetol substances.

3.
Acta Pharmaceutica Sinica ; (12): 773-778, 2023.
Article in Chinese | WPRIM | ID: wpr-965638

ABSTRACT

In this study, we established a novel bioassay to determine the activity of polyethylene glycolated recombinant human growth hormone (PEG-rhGH) using Nb2-11 cells. We performed experimental condition optimization and methodological verification, and then detected the relative potency of PEG-rhGH products using this method. We demonstrated that the bioactivity of PEG-rhGH in promoting Nb2-11 cell proliferation displays a dose-response relationship, which conformed to the four-parameter model. Using PEG-rhGH reference as a control, we analyzed the relative potency of six batches of PEG-rhGH products, as well as linearity, regression and parallelism of the obtained curves. The relative potency of six batches of PEG-rhGH products was 95% to 105%. These results implied that the new bioassay established may be employed in quality control of PEG-rhGH products.

4.
Acta Pharmaceutica Sinica ; (12): 760-766, 2023.
Article in Chinese | WPRIM | ID: wpr-965633

ABSTRACT

The goal of this work was to explore the prospect of standardized application of an in-vitro bioactivity assay for recombinant human follicle-stimulating hormone based on a reporter gene. The relative accuracy, intermediate precision, linearity and applicable range of the method were validated according to the General Rules of Chinese Pharmacopoeia 2020 edition Volume IV (9401). Three laboratories used this method to determine the in-vitro biological activities of six batches of drug product and three batches of drug substance manufactured by two different companies. The consistency of the potency determined by three laboratories, the intra-laboratory precision and inter-laboratory precision were analyzed. The method was optimized during the collaborative validation. The results of method validation meet the requirements of the General Rules of Chinese Pharmacopoeia 2020 edition Volume IV (9401). Aiming to resolve the problems found in the collaborative validation, the medium for cell seeding, the pre-diluted buffer solution of standard and sample, and the means of removing and discarding supernatant after stimulation were optimized. After optimization, there was no significant difference in the bioactivity among the different laboratories (P > 0.05), indicating statistical equivalency. Intra-laboratory and inter-laboratory precision were good and the geometric coefficient of variation (GCV%) were both less than 15%. In conclusion, the reporter gene assay has good intra-laboratory repeatability and inter-laboratory reproducibility and is suitable for analyzing recombinant human follicle-stimulating hormone drug product and drug substance by different manufacturers. It is expected to be used as a standardized method for the determination of the in-vitro bioactivity of such products.

5.
Chinese Journal of Biologicals ; (12): 1361-1367+1372, 2023.
Article in Chinese | WPRIM | ID: wpr-998391

ABSTRACT

@#Objective To develop and validate the real-time fluorescent quantitative PCR(Q-PCR)method for the detection of 8 murine viruses. Methods The specificity,sensitivity and precision of the Q-PCR method were verified by four laboratories,and the virus simulated contamination test and blind sample detection were carried out simultaneously,of which the detection results were compared. The Q-PCR method was used to detect 26 batches of monoclonal antibody cell lines for SARS-CoV-2 vaccine production and 15 batches of other products of murine origin. Results The Q-PCR method used for detecting 8 kinds of murine viruses had no cross reaction with the same family and genus or other murine viruses. Except the sensitivity of laboratory 2 to ectromelia virus(EctV/Mouse Pox,MPV)was 2 × 10~2copies/μL,the sensitivity of laboratory 2 to other 7 viruses and 3 other laboratories to 8 murine viruses was 2 × 10~1copies/μL. Except the inter-assay CV of the copy number of mouse adenovirus(MAdV)detected by laboratory 3 was 37. 58%,the intra-assay and inter-assay CVs of the Ct and copy number of other 7 viruses detected by laboratory 3 and those of 8 viruses detected by other 3 laboratories were all less than 25%.The sensitivity of virus simulated contamination test met the parameter requirements. The coincidence rate of blind sample detection results by 4 laboratories was 100%. All the 26 batches of monoclonal antibody cell lines for SARS-CoV-2 vaccine production and 15 batches of other murine derived products were negative for 8 murine viruses. Conclusion Q-PCR method for murine virus has good specificity,sensitivity and precision,and can be used for the detection of murine derived biological products.

6.
São Paulo; s.n; s.n; 2022. 79 p. tab, graf.
Thesis in Portuguese | LILACS | ID: biblio-1380631

ABSTRACT

A contaminação microbiana pode comprometer a eficácia e a segurança dos produtos farmacêuticos. Os testes de contagem microbiana são utilizados para avaliar a qualidade microbiológica de produtos farmacêuticos não estéreis, exigidos pela maioria dos compêndios farmacopeicos. Apesar disso, raramente é considerada a avaliação da incerteza de medição para testes de contagem microbiana, o que pode levar a falsas decisões quanto à conformidade/nãoconformidade. Neste trabalho avaliamos os efeitos de matriz nos testes de contagem microbiana e sua avaliação de incerteza top-down, e avaliamos a incerteza da medição utilizando a abordagem bottom-up, além de que estimamos os riscos do consumidor ou do produtor devido à incerteza da medição. As incertezas combinada e expandida são calculadas empregando-se a abordagem topdown consideraram a exatidão (recuperação) e a precisão como os principais componentes de incerteza. O componente de incerteza da exatidão foi o mais relevante em 59% das amostras estudadas, enquanto a precisão foi a principal fonte de incerteza em apenas 41% das amostras, sendo observado que quanto maior a interferência da matriz, maior o fator de incerteza e, consequentemente, maior a assimetria para o intervalo em torno da medida. A partir da abordagem bottom-up, foram identificadas e quantificadas três principais fontes de incerteza: fator de diluição, volume plaqueado e contagem das placas. A contribuição dessas fontes de incerteza depende do valor medido da carga microbiana em produtos farmacêuticos, a contribuição do fator de diluição e das incertezas do volume plaqueado aumentam com o aumento do valor medido, enquanto a contribuição da contagem das placas diminui com o aumento do valor medido. Foi possível avaliar o risco de decisões falsas devido à incerteza de medição, por meio das estimativas dos riscos do consumidor ou do produtor. Os riscos foram avaliados utilizando-se o método Monte Carlo. Portanto, foi demonstrado a relevância da avaliação da incerteza de medição para garantir a confiabilidade dos resultados dos testes de contagem microbiana e a apoiar a tomada de decisões quando a avaliação da conformidade/não-conformidade dos produtos farmacêuticos não estéreis


Microbial contamination can compromise the efficacy and safety of pharmaceutical products. Microbial counting tests are used to assess the microbiological quality of non-sterile pharmaceutical products required by most pharmacopoeia compendiums. Despite this, measurement uncertainty assessment for microbial count tests is rarely considered, which can lead to false compliance/non-compliance decisions. In this work we evaluated the matrix effects on microbial counting tests and their top-down uncertainty assessment, and evaluated measurement uncertainty using the bottom-up approach, inaddition to estimating the consumer's or producer's risks due to measurement uncertainty. The combined and expanded uncertainties calculated using the top-down approach considered accuracy (recovery) and accuracy as the main components of uncertainty. The uncertainty component of accuracy was the most relevant in 59% of the samples studied, while accuracy was the main source of uncertainty in only 41% of the samples, being observed that the greater the interference of the matrix, the greater the uncertainty factor and, consequently, the greater the asymmetry for the interval around the measurement. From the bottom-up approach, three main sources of uncertainty were identified and quantified: dilution factor, platelet volume and plaque count. The contribution of these sources of uncertainty depends on the measured value of microbial load in pharmaceutical products, the contribution of the dilution factor and uncertainties of the plated volume increase with the increase in the measured value, while the contribution of plate counting decreases with the increase of the measured value. It was possible to assess the risk of false decisions due to measurement uncertainty by estimating consumer or producer risks. The risks were evaluated using the Monte Carlo method. Therefore, the relevance of measuring uncertainty assessment has been demonstrated to ensure the reliability of microbial count test results and to support decision-making when assessing non-sterile pharmaceutical conformity/non-compliance


Subject(s)
Pharmaceutical Preparations/analysis , Efficacy , Uncertainty , Reproducibility of Results , Total Quality Management/methods , Compliance
7.
Acta Pharmaceutica Sinica ; (12): 2851-2856, 2022.
Article in Chinese | WPRIM | ID: wpr-941499

ABSTRACT

In this study, butaselen-2,‍6-dimethyl-‍β‍-cyclodextrin inclusion complexes were prepared by saturated aqueous solution method to improve the solubility of butaselen, so as to obtain its injection solutions. The content of butaselen in the inclusions was determined by high performance liquid chromatography (HPLC), and then the preparation process was optimized by orthogonal design using the inclusion ratio as an indicator. X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR) and scanning electron microscope (SEM) were used to verify the structure of the inclusions. The effects of the inclusions on the solubility and stability of butaselen were also investigated. The results showed that the optimized preparation process with a mass ratio of 1∶340, an encapsulation time of 3 h and an encapsulation temperature of 70 ℃ resulted in an encapsulation ratio of (91.24 ± 0.42) %, and the results of XRD, FTIR and SEM demonstrated the formation of inclusion complexes. The developed HPLC method is rapid, simple, accurate, applicable, specific and reproducible for the determination of butaselen content in butaselen cyclodextrin inclusion complexes, which can lay the foundation for the development of new butaselen dosage forms and clinical applications and provide technical support.

8.
Chinese Journal of Blood Transfusion ; (12): 1020-1023, 2022.
Article in Chinese | WPRIM | ID: wpr-1004114

ABSTRACT

【Objective】 To develop and verify high performance liquid chromatography (HPLC) detection for tromethamine (Tris) residues in human coagulation factor Ⅷ. 【Methods】 Alanine was used as internal standard, and AQC for pre-column derivation. Inertsil® ODS-SP was adopted, and acetic acid-sodium acetate buffer and acetonitrile were used for gradient elution at the flow rate of 1 mL/min and column temperature of 37℃. The 25 μL sample was loaded and determined by UV-detector with detection wavelength at 248 nm. This method was then verified. 【Results】 Glycine, sodium citrate and calcium chloride showed no interference with the detection of tromethamine (Tris) residues. The recovery rate of spike samples was within 90.0%~100.8%. The RSD in repeatability test were 2.5%, 0.7% and 1.2%, respectively, and in intermediate precision test 0.8%. The tromethamine (Tris) at concentrates of (0.5~4.0)μg/mL showed good linear relationship to the peak area to internal standard, of which the regression equation was Y=0.012 9X-0.000 782, R=0.999 97.The quantitative detection limit was 0.04μg/mL. 【Conclusion】 The HPLC for determination of tromethamine (Tris) residues in human coagulation factor Ⅷ was successfully developed, which showed good linearity as well as high specificity, precision and accuracy.

9.
Mongolian Medical Sciences ; : 43-50, 2021.
Article in English | WPRIM | ID: wpr-974448

ABSTRACT

Introduction@#Calycosin-7-O-β-D-glucoside is a glycosyloxyisoflavone that is calycosin substituted by a beta-D-glucopyranosyl residue at position at 7 via a glycosidic linkage. calycosin-7-O-β-D-glucoside, a calycosin derivative compound derived from Astragali Radix, has protective effect against ischemia/ reperfusion injury as well as bacterial endotoxin-induced vascular cell injury. A joint research team of the “Tsombo Pharm” Co., LTD and the Drug research Institute is conducting an experiment to produce a solution of “Astragalus mongholicus” injection prepared by Astragalus mongholicus bunge.@*Goal @#The aim of this study was to develop the validation method of Calycosin-7-O-β-D-glucoside in “Astragalus mongholicus” injection. @*Material and Methods@#As a test sample “Astragalus mongholicus” injection was produced by “Tsombo pharma” Co., LTD. The starndard Calycosin-7-O-β-D-glucoside was supplied from Xilong Scientific Co., Ltd. The reagent were high-performance liquid chromatography (HPLC) grade acetonitrile, formic acid, methanol and purified water. Shimadzu HPLC (CMB-20 A, UV detector Shimadzu SPD-20A was used as the analytical instrument and the analysis conditions were as follows Table 1.@*Results@#The calibration curves for Calycosin-7-O-β-D-glucoside were made by plotting the peak area versus the concentration for each analyte using regression analysis. Each calibration curve was obtained using six levels of concentrations in the range 12.5-100µg/ml. The linear correlation coefficient (R2) for all calibration curves was higher than 0.9981 for all analytes. The limit of detection and limit of quantitation for Calycosin-7-O-β-D-glucoside were in 10.37 µg/ml and 31.45 µg/ml. Accuracy and precision were assessed by analyzing five sets of samples, independently prepared at low (50%) middle (100%) and high (150%) concentrations. The RSD values of both repeatability and intermediate precision were below 0.68% and 0.618% the accuracy remaining between 95.55 to 101.71%. The resulting accuracy data were satisfactory for the quantitative analysis of Calycosin-7-O-β-D-glucoside in “Astragalus mongholicus” injection.@*Conclusions@#Finally, this method can be employed conveniently, reliably and successfully for the estimation of Calycosin-7-O-β-D-glucoside for routine quality contral and stability studies in “Astragalus mongholicus” injection.

10.
Mongolian Medical Sciences ; : 54-60, 2021.
Article in English | WPRIM | ID: wpr-974412

ABSTRACT

Introduction@#One of the main ingredients of Anar-5 tablets is Piper longium L. Piperine alkaloids are the main active ingredients of the Piper longum and have anti-inflammatory, antioxidant and gastric protection properties.In the framework of the standardization study of Anar-5 tablets, a method was developed to determine the content of piperine in highly perpormance liquid chromatography, and then it was sought to include it in the method of analysis of Anar-5 drugs.@*Goal@#Quantitative determination of piperine in Anar-5 tablets and validate the method@*Material and Methods@#The research was conducted in the Chemistry and Chemical Technology Laboratory of the Research Center of the Institute of Traditional Medicine and Technology. And Anar-5 tablets (serial number 04012020) that are produced for experimental were used in the research. The standard substance, piperine alkaloids, was purchased from Green Chemistry.Purification of HPLC (organic solvent methanol, 99.9%, distilled water) was used. The EX 1600 HP/ PUMP high-performance liquid chromatography instrument (column Arcus EP+-C18, 5µm, 4.6x250 mm) and the organic solvent filter 0.45 μm syringe filter were used. The methodology related to this research was discussed and approved at the online meeting of the Ethics Committee of the Academy of Sciences on January 26, 2021. SPSS 16 software was used to statistically program the survey results.@*Results @#According to the above method, the retention time of the standard piperine is 10.38± 0.02 minutes, and the retention time of the piperine in Anar-5 tablets is 10.42±0.033 minutes. Relative velocity deviation RSD 1.077%, accuracy 0.65446±0.0068mg, stability 0.61298±0.013mg, capture time 10.42±0.033 minutes, relative standard deviation RSD≤2%, specificity 10.35 minutes, The equation of a line constructed with a standard curve is y=43360x-33587 and the correlation coefficient R2=0.9989. The piperine content of Anar-5 tablets was determined to be 0.61298±0.013 mg. The LOD and LOQ for piperine were in 2.268 μg/ml and 6.873 μg/ml, respectively.@*Conclusion@#The content of piperine in Anar-5 tablets can be determined by the HPLC method, and the appropriate conditions for this method have been established. The HPLC method is unique, accurate, linear, and stable, and meets ICH Q2 (R1) guideline criteria.

11.
Acta Pharmaceutica Sinica ; (12): 2276-2281, 2021.
Article in Chinese | WPRIM | ID: wpr-887037

ABSTRACT

The high performance liquid chromatography-fluorescence micelle assay (HPLC-FMA) method for the content determination of polysorbate 80 in monoclonal antibody drugs was validated to study its applicability and transferability between various laboratories, and the feasibility to be included in the Chinese Pharmacopoeia. Both J.T. Baker and Nanjing Well-sourced polysorbate 80 was used in the collaborative validation of polysorbate 80 content analysis in seven different laboratories. The results show that when the protein concentration was no more than 20 mg·mL-1 and the concentration of polysorbate 80 ranged from 0.05 to 0.5 mg·mL-1, the method had good specificity. The recovery rates of the spiked samples ranged from 92.20% to 117.70% for J.T.Baker and from 93.90% to 117.20% for Nanjing Well. The intra-laboratory precision (%RSD) was less than 4.30% for J.T. Baker, and less than 2.60% for Nanjing Well, while the overall precision was less than 5.45% for J.T. Baker, and less than 6.70% for Nanjing Well. The linear correlation coefficient was more than 0.98 for J.T. Baker and more than 0.99 for Nanjing Well. The results of the collaborative validation prove that the HPLC-FMA method has good accuracy, precision, linearity, and specificity, and could be used for release control analysis of polysorbate 80 content in monoclonal antibodies across different laboratories.

12.
Journal of Pharmaceutical Analysis ; (6): 68-76, 2021.
Article in Chinese | WPRIM | ID: wpr-883500

ABSTRACT

In this study,we developed a simple screening procedure for the determination of 18 anthelmintics(including benzimidazoles,macrocyclic lactones,salicylanilides,substituted phenols,tetrahydropyr-imidines,and imidazothiazoles)in five animal-derived food matrices(chicken muscle,pork,beef,milk,and egg)using liquid chromatography-tandem mass spectrometry.Analytes were extracted using acetonitrile/1%acetic acid(milk and egg)and acetonitrile/1%acetic acid with 0.5 mL of distilled water(chicken muscle,pork,and beef),and purified using saturated n-hexane/acetonitrile.A reversed-phase analytical column and a mobile phase consisting of(A)10 mM ammonium formate in distilled water and(B)methanol were used to achieve optimal chromatographic separation.Matrix-matched standard calibration curves(R2≥0.9752)were obtained for concentration equivalent to ×1/2,×1,×2,×3,×4,and ×5 fold the maximum residue limit(MRL)stipulated by the Korean Ministry of Food and Drug Safety.Recoveries of 61.2-118.4%,with relative standard deviations(RSDs)of ≤19.9%(intraday and interday),were obtained for each sample at three spiking concentrations(×1/2,×1,and ×2 the MRL values).Limits of detection,limits of quantification,and matrix effects were 0.02-5.5 μg/kg,0.06-10 μg/kg,and-98.8 to 13.9%(at 20 μg/kg),respectively.In five samples of each food matrix(chicken muscle,pork,beef,milk,and egg)purchased from large retailers in Seoul that were tested,none of the target analytes were detected.It has therefore been shown that this protocol is adaptable,accurate,and precise for the quantification of anthelmintic residues in foods of animal origin.

13.
Acta Pharmaceutica Sinica B ; (6): 3925-3934, 2021.
Article in English | WPRIM | ID: wpr-922450

ABSTRACT

T cell immunoglobulin and ITIM domain (TIGIT) is a novel immune checkpoint that has been considered as a target in cancer immunotherapy. Current available bioassays for measuring the biological activity of therapeutic antibodies targeting TIGIT are restricted to mechanistic investigations because donor primary T cells are highly variable. Here, we designed a reporter gene assay comprising two cell lines, namely, CHO-CD112-CD3 scFv, which stably expresses CD112 (PVRL2, nectin-2) and a membrane-bound anti-CD3 single-chain fragment variable (scFv) as the target cell, and Jurkat-NFAT-TIGIT, which stably expresses TIGIT as well as the nuclear factor of activated T-cells (NFAT) response element-controlled luciferase gene, as the effector cell. The anti-CD3 scFv situated on the target cells activates Jurkat-NFAT-TIGIT cells through binding and crosslinking CD3 molecules of the effector cell, whereas interactions between CD112 and TIGIT prevent activation. The presence of anti-TIGIT mAbs disrupts their interaction, which in turn reverses the inactivation and luciferase expression. Optimization and validation studies have demonstrated that this assay is superior in terms of specificity, accuracy, linearity, and precision. In summary, this reliable and effective reporter gene assay may potentially be utilized in lot release control, stability assays, screening, and development of novel TIGIT-targeted therapeutic antibodies.

14.
Chinese Journal of Blood Transfusion ; (12): 227-231, 2021.
Article in Chinese | WPRIM | ID: wpr-1004550

ABSTRACT

【Objective】 To develop and verify a kinetic method for the determination of prekallikrein activator (PKA) content. 【Methods】 The optimal reaction conditions were determined by comparing the factors of pH and ionic strength of different sample dilution buffers, incubation time of each procedure, and incubation temperature. The accuracy, specificity, precision, linearity, stability and durability of the method were validated. 【Results】 The sample was diluted with 0.05 mol/L Tris-HCl buffer (pH8.5, containing 0.15 mol/L NaCl) and incubated by prekallikrein (PK) at 37℃ for 20 min. After that, the substrate S-2302 was added. Within 10 min before the measurement, the absorbance change rate reached △A405/min. The validation results indicated that the linear range of the method was (0.5~4.0)IU/mL, while the recovery of calibration standard was 96.9%~103.7% with the R2 value more than 0.99. The specificity test showed that human serum albumin, excipients of intravenous human immunoglobulin (pH4), low pH and protein content had no significant effect on the detection of PKA, The recovery rates of standard sample solution in the specificity experiment were 98.0% (0.9% sodium chloride solution), 95.3% (0.46% sodium caprylate solution), 96.7% (10% maltose solution, pH4.0), 94.0%(20%BSA), and 94.0%(5%BSA, pH4.0), respectively. The accuracy and precision of the method can meet requirements in the range between 0.5 and 4.0 IU/mL. The inter-batch recovery rate of quality control samples were between 96.4%~109.5% with the coefficients of variation(CV) between 0.2%~6.9%, while the intra-batch recovery rate were between 101.5%~102.9% with the CV between 2.6%~5.9%. The linearity, accuracy and precision of the assay can meet the requirements when PK and S-2302 were placed at room temperature for less than 6 hours, with the recovery rate of quality control samples between 94.9%~109.9%. The end-point method and kinetic method were used to determine the PKA in 20 batches of human serum albumin, and the consistency showed that there was no significant difference between the two methods(P>0.05). 【Conclusion】 A kinetic method for determination of PKA content with good linearity, specificity, accuracy, precision, stability and durability has been established. Compared with the method in ChP, the new method is more convenient, accurate and rapid to determine the content of PKA in human albumin and human immunoglobulin (pH4) for intravenous injection.

15.
J Ayurveda Integr Med ; 44013; 11(3): 277-280
Article | IMSEAR | ID: sea-214033

ABSTRACT

Background: Viscum articulatum Burm. (Family: Loranthaceae) is commonly known as mistletoe. Inayurveda, the plant parts are used in “Kapha”, “Vata”, diseases of the blood, ulcer, and epilepsy. The plantparts are also used in urinary tract infection and wound infection. The plant contains five triterpenoidssuch as a-amyrin, lupeol, betulin, betulinic acid and oleanolic acid, exhibiting several pharmacologicalactivities including antimicrobial, anti-HIV, antitumor, antiviral activity.Objective: To ensure the content of uniformity of oleanolic acid, a RP-HPLC method has been developedfor estimation of oleanolic acid in V. articulatum aerial part.Material and methods: The RP-HPLC method was carried out in reverse phase C18 column, using methanol and water as mobile phase in the ratio of 95:5 (v/v), at the flow rate of 1 mL/min. The pH of aqueousphase was adjusted 3.2 with 1% (v/v) glacial acetic acid. The lmax was set at 210 nm.Results: The retention time of oleanolic acid was found at 21.5 ± 0.05 min. The linearity of the response wasfound to be 10e800 mg/mL. The coefficient of determinants of oleanolic acid was found to be (r2) 0.995 andequation Y ¼ 19462X þ 16,172. The LOD and LOQ were found to be for oleanolic acid (1.96% w/w) 0.197 ± 0.63and 0.623± 0.87 mg/mL, respectively. The developed method was accurate, specific, precise and reproducible.Conclusion: This RP-HPLC may be useful for quantitative estimation of the chemical constituents presentin the plant extract as well as the quality assessment of the herbal product.

16.
Int J Pharm Pharm Sci ; 2020 Jul; 12(7): 45-50
Article | IMSEAR | ID: sea-206124

ABSTRACT

Objective: The main objective of the research work is to develop and validate a rapid UHPLC method for the estimation of assay and its related substances of Trichostatin A (TSA) in pharmaceutical samples. Methods: The UHPLC method developed for chromatographic separation between TSA and its related compounds on Poroshell 120 SB C18(50×4.6) mm; 2.7 µm RRLC column using Agilent RRLC (UHPLC) system with linear gradient elution. Results: The developed UHPLC method has shown excellent chromatographic separation between TSA and its related compounds within 12 min run time, during validation experiments, specificity study revealed that the peak threshold was more than the peak purity and no purity flag was observed. Repeatability, intra, and inter-day precision results were well within the tolerable limits. Limits of detection concentrations were found between 0.075 to 0.077 ppm and the limit of quantitation is between 0.252 to 0.258 ppm for related compounds and TSA. The related substances method recoveries were found between 80 and 120 % and assay method recovery was found between 98.0 to 102.0%. Conclusion: The developed method capability was proven for the assay of TSA and its related compounds in pharmaceutical samples and the method shows eco-friendlier than routine, conventional HPLC methods in terms of analysis time, cost and HPLC effluent waste.

17.
Int J Pharm Pharm Sci ; 2020 Jun; 12(6): 76-80
Article | IMSEAR | ID: sea-206113

ABSTRACT

Objective: The objective of the present work was to establish a simple, precise, accurate and robust method for simultaneous estimation of gallic acid, curcumin and piperine from the marketed ayurvedic formulation by liquid chromatography. Methods: The separation was carried out on Hemochrom C18 Column (250 mm × 4.6 mm ID, 5 µm pore size) with a mobile phase methanol: acetonitrile: water (pH 3.2adjusted by using orthophosphate acid) in the ratio 70:20:10v/v by isocratic elution modeat 25 °C and the flow rate was setat0.8 ml/min. The analysis was carried out atisoabsorptive wavelength of 295 nm. Results: The retention time of gallic acid, curcumin and piperine was found to be 3.3(±0.2), 4.7 (±0.2) and 5.6 (±0.2) min, respectively. The linearity range for gallic acid, curcumin and piperine was found to be 10-70 μg/ml, 20-80 µg/ml and 2-14 µg/ml, respectively with the coefficient of linear regression greater than 0.99 for all markers. Mean percent recoveries for gallic acid, curcumin, and piperine were found within the limit of acceptance (99-100%). The percent relative standard deviation (%RSD) for precision and robustness was found less than 2%, which indicates the method is precise and robust. The developed method applied for quantification of these markers from the marketed ayurvedic formulation of Dekofcyn tablet. Conclusion: The developed method was found to be simple, rapid, precise and reproducible for standardization of Dekofcyn tablet and can be useful for other formulations containing these three markers.

18.
Rev. ciênc. farm. básica apl ; 41: [9], 01/01/2020. tab, ilus
Article in English | LILACS | ID: biblio-1128568

ABSTRACT

The substance 4-Aminobenzamidine dihydrochloride (4-AD) is one of the degradation products of diminazene aceturate and has demonstrated antiglaucomatous potential. Glaucoma is the second leading cause of blindness worldwide; thus, new therapeutic alternatives must be studied, for example, the molecule 4-AD vehiculated into polymeric inserts for prolonged release. The present work aims to develop and validate an analytical method to quantify 4-AD in pharmaceutical ophthalmic forms. A HPLC was used with UV-Vis detector, at 290 ƞm and ACE® C18 column (125 × 4.6 mm, 5 µm), in which the mobile phase consists of phosphate buffer (pH 7.4) and triethylamine (30 mmol/L), under an isocratic flow of 1.0 mL/min. The retention time of 3.2 minutes was observed. The method was developed and validated in accordance with ANVISA recommendations and ICH guides. The linearity range was established between the concentrations 5 and 25 µg/mL (correlation coefficient r = 0.993). The accuracy, repeatability, and intermediate precision tests obtained a relative standard deviation less than or equal to 5%. In addition, the method was considered selective, exact. and robust, with pH being its critical factor. Therefore, the HPLC analysis method is robust and can be used to quantify 4-AD in pharmaceutical forms for ocular application.(AU)


Subject(s)
Ophthalmic Solutions/pharmacology , Vasodilator Agents , Benzamidines/pharmacology , Diminazene/analysis , Glaucoma , Chromatography, High Pressure Liquid , Validation Studies as Topic
19.
Braz. J. Pharm. Sci. (Online) ; 56: e17784, 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1089223

ABSTRACT

Two simple, selective and sensitive spectrophotometric methods were developed and validated for the determination of valganciclovir hydrochloride (VLGH) in pure drug and tablets. The first method was based on the reduction of iron(III) to iron(II) by VLGH and subsequent formation of iron(III)-ferricyanide complex (Prussian blue) in acid medium which was measured at 730 nm (method A). In the second method (method B), permanganate was reduced by VLGH to bluish green manganate in alkaline medium and the absorbance was measured at 610 nm. The absorbance measured in each case was related to VLGH concentration. The experimental conditions were carefully studied and optimized. Beer's law was obeyed over the concentration ranges of 2.5-20.0 and 2.0-40.0 µg mL-1 for method A and method B, respectively, with corresponding molar absorptivity values of 1.28×104 and 6.88×103 L mol-1 cm-1. The limits of detection (LOD) and quantification (LOQ) were 0.11 and 0.33 µg mL-1 (method A) and 0.21 and 0.64 µg mL-1 (method B). Within-day and between-day relative standard deviations (%RSD) at three different concentrations levels were < 2.4%, and the respective relative errors (%RE) were ≤ 3%. The proposed methods were successfully applied to the determination of VLGH in tablets, and the results confirmed that the proposed methods were equally precise and accurate as the official method.

20.
China Journal of Chinese Materia Medica ; (24): 2180-2185, 2020.
Article in Chinese | WPRIM | ID: wpr-827964

ABSTRACT

Stilbenes is a class of natural polyphenols with 1,2-diphenylethylene as the skeleton structure which have structural and active diversity. However, there are fewer studies on their metabolic process, which limits the in-depth research and development of such components. An UPLC-MS/MS method simultaneously determining contents of ten stilbenes was firstly established in this study and applied to study the ten stilbenes of peony seed coats in the serum of C57 mice.Piceatannol was the internal standard, and methanol was used for protein precipitation, UPLC-MS/MS with negative ion mode was used for analysis, and the method was validated.The serum samples were collected and detected after mice being oral administered with 800 mg·kg~(-1) peony seed coat extracts for 8 weeks. The results showed that suffruticosol A, suffruticosol B, suffruticosol C, trans-ε-viniferin, cis-gnetin H, trans-suffruticosol D and trans-gnetin H were detected in serum samples, and the highest is suffruticosol A. The method is simple and quick with high specificity and sensitivity, and it is suitable for quantitative determination of ten stilbenes in the serum of mice.


Subject(s)
Animals , Mice , Chromatography, High Pressure Liquid , Chromatography, Liquid , Paeonia , Reproducibility of Results , Seeds , Chemistry , Stilbenes , Tandem Mass Spectrometry
SELECTION OF CITATIONS
SEARCH DETAIL